Accident: 200260602 - Electric Shock - Contact With Overhead Line Thru Boom
Accident: 200260602 -- Report ID: 0627100 -- Event Date: 04/21/1999 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
116485533 | 04/21/1999 | 3271 | Arkhola Sand & Gravel Company | ||||
An employee was using the boom on a boom truck to unload concrete block at a prison. The boom contacted a 7600-volt overhead power line. The employee, who was holding the pendant controls for the boom, was electrocuted. (He was pronounced dead at the scene.) | |||||||
Keywords:
boom truck, overhead power line, electrical, boom, electrocuted, e gi ia, truck boom
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 116485533 | Fatality | Electric Shock | Occupation not reported |