Accident Report Detail
Accident: 200210391 - Ten Employees Injured When Exposed To Hydrogen Sulfide Gas
Accident: 200210391 -- Report ID: 0626000 -- Event Date: 12/14/1998 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
302099890 | 12/14/1998 | 2911 | Coastal Refining & Marketing, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
302099908 | 12/14/1998 | 1799 | Repcon, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
302099890 | 12/14/1998 | 2911 | Coastal Refining & Marketing, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
302099908 | 12/14/1998 | 1799 | Repcon, Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
302099890 | 12/14/1998 | 2911 | Coastal Refining & Marketing, Inc. | ||||
Employees #1 through #10 worked at a crude oil refinery at which nearby process units (crude oil and gas oil treater) were undergoing a planned turnaround. The units had staggered shutdown and startup schedules, and they shared some product transfer piping leading to storage. When the product flow was rerouted by operations prematurely, sour naphtha liquid was released into the crude unit from an open connection installed on a new 6 in. piping section that served as an exchanger bypass line. The low-pressure release lasted for several minutes and allowed clouds of toxic hydrogen sulfide gas to accumulate in and around the nearby control room and through nearby process units. Emergency alarm and evacuation procedures were not executed according to plan. Operators responding in the field at first attempted rescue efforts without using emergency air packs, ultimately adding to the total of exposed employees. Numerous exposures to the evolved sour gas resulted in injury to both plant and contractor employees. Employees #1 through #10 were transported to the hospital, and Employees #2 through #4, #9, and #10 were admitted. None experienced permanent effects. Subsequent investigation revealed weaknesses and discrepancies in the plant lockout/tagout program, and poor implementation and upkeep of the process safety program. Unit isolation blinds and lockout/tagout blinds for the equipment were not clear to the operators due to poor tracking. Operating procedures were both outdated (e.g., the use of checklists) and/or unclear, such as to how to perform the final stages of unit startup. | |||||||
Keywords:
ppe, work rules, inhalation, air contamination, emergency response, hydrogen sulfide, lockout, chemical reaction, chemical vapor, refinery
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Refinery | Maintenance or repair | $1,000,000 to $5,000,000 | 2 | 25 | |||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 302099890 | Non Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
2 | 302099890 | Non Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
3 | 302099890 | Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
4 | 302099908 | Hospitalized injury | Other | Construction laborers | FallDist: FallHt: Cause: Installing equipment (HVAC and other) FatCause: Asphyxiation/inhalation of toxic vapor |
||
5 | 302099890 | Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
6 | 302099890 | Non Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
7 | 302099890 | Non Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
8 | 302099890 | Non Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |
||
9 | 302099908 | Hospitalized injury | Other | Welders and cutters | FallDist: FallHt: Cause: Installing equipment (HVAC and other) FatCause: Asphyxiation/inhalation of toxic vapor |
||
10 | 302099890 | Hospitalized injury | Other | Chemical technicians | FallDist: FallHt: Cause: FatCause: |