Accident Report Detail
Accident: 200090611 - Employee Killed When Mobile Gantry Crane Overturns
Accident: 200090611 -- Report ID: 0112300 -- Event Date: 07/25/2007 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
310157375 | 07/25/2007 | 1623 | Eastern Piping And Engineering Inc. | ||||
On July 25, 2007, Employee #1 was disassembling a Spanco T-series three-way adjustable mobile gantry. He hooked a chain fall and a come-along on opposite ends of the A-frame sections of the gantry. He then tightened the two devices, which pulled the bottom and the top of the gantry toward one another. Employee #1 then pulled the adjusting pins from the legs of the gantry, which caused the gantry legs on one end to compress into each other. The gantry fell over, striking Employee #1 as tried to flee the collapsing structure. He was crushed and killed. | |||||||
Keywords:
dismantling, unsecured, construction, gantry crane, crushed, struck by, crane, overturn
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Sewer/water treatment plant | Alteration or rehabilitation | $250,000 to $500,000 | 2 | X | |||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | Construction |
1 | 310157375 | Fatality | Bruise/Contus/Abras | Occupation not reported | FallDist: FallHt: Cause: FatCause: Struck by falling object/projectile |