Accident Report Detail
Accident Summary Nr: 200033033 - Employees Chemically Burned by Leaking Dimethyl Sulfate Pipe
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 310177514 | 06/21/2007 | 2869 | 325199 | Stepan Company |
Abstract: At 11:30 a.m. on June 20, 2007, Employees #1, #2, #3, and #4, who worked for Brand Scaffolding Company, and Employees #5, and #6, who worked for Atlantic Plant Services Company, and Employees #7 and #8, who worked for Stepan Company, a chemical manufacturer, were hospitalized after being exposed to dimethyl sulfate (DMS) in the ethoxylation area where it was used in reactors 4 and 5. Employee #7 was an operator who moved bags containing chemicals into the area in order to add it to reactor 4. Employee #8 was a mechanic that worked unplugging an auger at reactor 4. Employees #7 and #8 started working at 7 a.m. at reactor 4. Employees #1, #2, #3, and #4 dismantled a scaffold at a platform at the reactors. Employees #5 and #6 removed and installed new insulation on piping at a platform at the reactors. The host employer did not become aware that employees were exposed to DMS until about 2 p.m., when workers were discovered having chemical burns. Employees worked on a raised platform around the two reactors. In order to enter and leave the area, they walked along a path between two the reactors that was only 30 inches wide, and a pipe that contained DMS which ran overhead between the reactors. The piping system normally operated at 5 psi, but thermal expansion of DMS caused pressures over 300 psi and caused a valve on the overhead pipe to leak this extremely hazardous compound down onto employees that worked beneath the pipe.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 2 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 3 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 4 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 5 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 6 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 7 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations | ||
| 8 | 310177514 | Non Hospitalized injury | Burn(Chemical) | Machinery maintenance occupations |