Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200032944 - Employee Is Injured When Exposed to Acid

Accident Summary Nr: 200032944 -- Report ID: 0521700 -- Event Date: 05/04/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31017653205/08/20073369331528Chicago Magnesium Casting Company

Abstract: On May 4, 2007, Employee #1, was etching aluminum castings in an acid solution containing approximately 3 units of hydrofluoric acid and 30 units of nitric acid. The acid solution and etching procedure was performed in a drum with no local exhaust ventilation. A chemical reaction ensued, resulting in a significant release of orange and brown fume in the work area and possibly a spill. Management was alerted to the area and got the reaction under control. The employee did not complain of injury or adverse health symptoms and continued working for approximately three hours. Employee #1 clocked out and left work before his shift ended without notifying management. Later that evening, St. Francis Hospital notified the Fire Department that they were treating Employee #1 for acid exposure and requested the material safety data sheets (MSDS) for the acid solution. The employee was transferred to Loyola Hospital in critical condition.

Keywords: EXHAUST SYSTEM, VENTILATION, HYDROFLUORIC ACID, CASTING, INHALATION, CHEMICAL REACTION, NITRIC ACID, CHEMICAL VAPOR, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310176532 Hospitalized injury Burn(Chemical) Chemical technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close