Accident Report Detail
Accident Summary Nr: 170872162 - EMPLOYEE FELL WITH AERIAL LIFT IN TIPOVER
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 125773838 | 10/29/1998 | 1731 | 0 | Pacific Gas & Electric Company |
Abstract: A power line crew was moving an existing overhead power line. Due to the age of one of the utility poles supporting the line, the employer determined that it would not be safe to climb. Thus, the employees were using an aerial lift. A power line worker on the crew positioned the aerial lift truck but did not extend the outriggers before raising the boom. As he maneuver the bucket to the old pole, he exceeded the rated angle for operating the aerial lift without outriggers, and it tipped over. The employee fell with the bucket and incurred a serious head injury. He was hospitalized for his injuries.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Powerline, transmission line | Maintenance or repair | Under $50,000 | 40 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 125773838 | Hospitalized injury | Fracture | Electrical power installers and repairers | Distance of Fall: feet Worker Height Above Ground/Floor: 20 feet Cause: Fencing, installing lights, signs, etc. Fatality Cause: Fall from/with bucket (aerial lift/basket) |
Translate