Accident Report Detail
Accident Summary Nr: 170725949 - Employees injured while checking heat exchanger for leak
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 111746293 | 04/19/1993 | 2911 | 0 | Chevron U.S.A. |
Abstract: Employee #1 was checking for a leak on a heat exchanger. There was only a 90 psig nitrogen pressure during the leak test; normally it would be 150 psig. Employee #1 was struck by the heat exchanger partition assembly. Employee #2 twisted around in a reflexive movement, injuring his neck and back. The separated exchanger partition assembly and heat exchange bundle were not retained. Employee #1 was hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111746293 | Hospitalized injury | Dislocation | Mechanical engineers | ||
| 2 | 111746293 | Non Hospitalized injury | Strain/Sprain | Specified mechanics and repairers |