Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 170366165 - Two Employees Injured In Blast Furnace Explosion

Accident: 170366165 -- Report ID: 0551800 -- Event Date: 11/29/2001
InspectionOpen DateSICEstablishment Name
30405863911/30/20011629Correct Construction Inc.
On November 29, 2001, Employee #1 and Employee #2, pipe fitters, were performing hot work on a section of a 72-in. gas main that was being replaced on a blast furnace, D stove system. An explosion occurred in the blast furnace gas main. Employee #1 and Employee #2 both received minor burses, contusions, and abrasions.
Keywords: blast furnace, gas, explosion, abrasion, pipe, contusion
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Manufacturing plant Maintenance or repair $50,000 to $250,000
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 304058639 Non Hospitalized injury Bruise/Contus/Abras Welders and cutters FallDist:
FallHt:
Cause: Steel Erection Of Solid Web-Welding/Burning/Grindi
FatCause: Fire/explosion
2 304058639 Non Hospitalized injury Bruise/Contus/Abras Construction laborers FallDist:
FallHt:
Cause: Steel Erection Of Solid Web-Welding/Burning/Grindi
FatCause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.