Accident Report Detail
Accident Summary Nr: 170340491 - Employee burned in flash fire
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 102931045 | 12/01/1992 | 3272 | 0 | Atlantic Precast Concrete, Inc. |
Abstract: Employee #1 entered a concrete mold (confined space) to light a liquid petroleum gas, direct- fired heater after it had gone out. He smelled gas and waited 5 to 10 minutes before relighting. Once relighted, the heater created a flash fire that severely burned Employee #1. Deficiencies included a lack of proper confined space entry and hot work procedures such as no permit; poor ventilation; location of a 100 lb capacity LP-gas cylinder within 1 to 2 ft of the heater; inadequate LP-gas hose assembly; non-qualified LP-gas cylinder; inadequate employee training; failure of the heater safety device (a thermoelectric valve) to prevent gas flow when the flame was extinguished.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102931045 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate