11987778511/20/19922038Fsi
At about 7:45 a.m. on November 20, 1992, Employee #1 was operating a Seal Rite machine. The machine consists of a conveyor that transports frozen foods in trays to the sealer where plastic is heat-sealed on the trays of frozen foods. The front of the sealer enclosure is guarded by a bar that runs across the opening where the trays enter the sealer. When the bar is lifted, the machine automatically stops. All enclosure guards are also interlocked and shut off the machine when the guards are removed. There is an over-ride control button that was designed to over-ride all safety bars and interlocks. The over-ride power control was located at hip height and was not protected against accidental contact. Employee #1 reached over when she saw an empty tray and part of her body contacted the over-ride power control. The machine kept on running, drawing her right hand into the heat roller. Employee #1 suffered third-degree burns to her four fingers and the back of her hand. She was taken to Western Medical Group for treatment and was released from the hospital on November 28, 1992. A serious violation of T8CCR 4000(d) was cited because the over-ride power control was not designed, installed, or located so that it could not be operated from accidental contact with objects or parts of the body.
Keywords: burn, heat, finger, control lever, equipment operator, struck against, caught by, roller--mach/part, started in gear, nip point
Employee # Inspection Age Sex Degree Nature Occupation
1 119877785 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close