Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170096853 - Employee crushed to death by overloaded crane boom

Accident Summary Nr: 170096853 -- Report ID: 1055360 -- Event Date: 11/03/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11552854911/03/199317210Root Paint & Glass Inc Dba Root Paint Inc

Abstract: Employee #1 was helping to lift equipment off a roof with a crane. The weight of the equipment was not determined before it was lifted and the crane was overloaded. This, along with the lack of proper maintenance of the crane, caused the boom to collapse onto Employee #1. He died.

Keywords: COLLAPSE, INADEQUATE MAINT, CRANE BOOM, WORK RULES, OVERLOADED, CONSTRUCTION, EQUIPMENT FAILURE, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115528549 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.