Accident Report Detail
Accident Summary Nr: 14550990 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 18171892 | 02/18/1992 | 1629 | 0 | M. A. Mortenson Company |
Abstract: A CRANE OPERATOR, A SAW SHOP FOREMAN, AND A MECHANIC WERE UNDER A CRANE, REMOVING AN INSPECTION PLATE SO THAT THE CUTTING DOGS FOR THE SKID STEER MECHANISM COULD BE REPAIRED. APPARENTLY, THE CRANE OPERATOR HAD ACCIDENTALLY MOVED THE BOOM LEVER SOME TIME EARLIER. SINCE THIS LEVER WAS NOT SELF-CANCELLING, THE BOOM GRADUALLY LOWERED AND CONTACTED A 34.5-KILOVOLT OVERHEAD POWER LINE. THE MECHANIC, WHO WAS IN CONTACT WITH THE CRANE, WAS ELECTROCUTED. THE OTHER TWO EMPLOYEES WERE NOT INJURED.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18171892 | Fatality | Electric Shock | Heavy equipment mechanics |