Accident Report Detail
Accident Summary Nr: 14530026 - EMPLOYEE CRUSHED, ANOTHER STRUCK BY FALLING POST DRIVER
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 101526119 | 12/07/1987 | 1799 | 0 | National Fence & Granite Co. Inc. |
Abstract: ON DECEMBER THIRD, 1987, EMPLOYEE #1 WAS OPERATING A POST DRIVER SETTING GUARD RAIL POSTS. EMPLOYEE #2 WAS PLACING POSTS IN POSITION TO BE DRIVEN. AS THE TRUCK WAS BEING POSITIONED TO DRIVE THE NEXT POST, THE BASE PLATE CAUGHT ON THE REAR OF THE POST, CAUSING THE TOP OF THE BOOM TO MOVE FORWARD. IN TURN, THIS CAUSED A CYLINDER TO BREAK LOOSE FROM THE BOOM ASSEMBLY. THE BOOM, WITH ITS ATTACHED 1500 POUND WEIGHT, FELL FORWARD, STRIKING EMPLOYEE #1 AND CRUSHING HIM TO DEATH. EMPLOYEE #2, THE HELPER, WAS STRUCK IN THE BACK AND SHOULDER. HE WAS HOSPITALIZED WITH BACK INJURIES.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101526119 | Fatality | Other | Machine operators, not specified | ||
| 2 | 101526119 | Hospitalized injury | Other | Helpers, construction trades |
Translate