Accident Summary Nr: 14503452 - One employee killed, nine injured by carbon monoxide

Accident Summary Nr: 14503452 -- Report ID: 0729700 -- Event Date: 01/25/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1827127001/27/198730110Goodyear & Tire & Rubber Co.

Abstract: Employees #1 and #2, both mechanics, were assigned to repair a bucket elevator bearing in an underground, 14 ft deep carbon pit. The pit had two access openings, but was otherwise enclosed. Employee #2 left the pit to get some tools. When he returned, he saw Employee #1 lying unconscious at the bottom of the pit near one of the openings. During the rescue effort, Employees #2 through #10 entered the pit, became dizzy, and experienced headaches. After a long period, they were able to retrieve Employee #1 from the pit using a rope and sling. Employee #1 died, and Employees #2 through #10 were hospitalized for carbon monoxide poisoning. Later, a smoldering fire in the carbon black spillage was discovered to be the source of the carbon monoxide. Causal factors contributing to this accident include: significant carbon black accumulation in the pit; lack of preparation for entering a confined space, including failure to conduct atmospheric testing, poor or no employee training, and lack of rescue equipment; and lack of ventilation in the pit.

Keywords: VENTILATION, CONFINED SPACE, WORK RULES, INHALATION, PIT, POISONING, HOUSEKEEPING, OVEREXPOSURE, UNTRAINED, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 18271270 Fatality Asphyxia Occupation not reported
5 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
6 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
7 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
8 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
9 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported
10 18271270 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.