Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14464234 - EXPLOSION AND FIRE DURING ETHANOL SPILL CLEANUP

Accident Summary Nr: 14464234 -- Report ID: 0551800 -- Event Date: 08/13/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
270109208/27/198528340Eli Lilly And Company

Abstract: EMPLOYEE #1 WAS FILLING A 55 GALLON STOCKPOT WITH #SD3A ALCOHOL FROM A FILL LINE. HE LEFT HIS WORK STATION WITHOUT STOPPING THE ALCOHOL FLOW. THE STOCKPOT OVERFILLED, SPILLING 20 GALLONS OF ALCOHOL ONTO THE FLOOR. IT IS SUSPECTED THAT EMPLOYEE #1 ATTEMPTED TO CLEAN THE SPILL, USING AN ELECTRIC, NONAPPROVED FLOOR SCRUBBER. AN EXPLOSION AND FLASH FIRE RESULTED, CAUSING THIRD DEGREE BURNS OVER 60% OF EMPLOYEE #1'S BODY. HE DIED 13 DAYS LATER.

Keywords: BURN, ALCOHOL, FLAMMABLE VAPORS, WORK RULES, FIRE, EXPLOSION, SPARK, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2701092 Fatality Burn/Scald(Heat) Mixing and blending machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.