Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14456487 - FINGER AMPUTATED IN PRESS BRAKE

Accident Summary Nr: 14456487 -- Report ID: 0854910 -- Event Date: 03/27/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
327938704/01/198534420Futura Home Products

Abstract: EMPLOYEE #1, 39 YEARS OLD, WAS A PRESS BRAKE OPERATOR. SHE WAS PERFORMING HER JOB ON MARCH 27, 1985, AT APPROXIMATLEY 1:45 PM WHEN THE ACCIDENT OCCURRED. AS SHE WAS CRIMPING AN ALUMINUM THRESHOLD IN THE PRESS, BOTH HANDS WERE CAUGHT NEAR THE FIRST AND SECOND JOINT. HER LEFT INDEX FINGER WAS AMPUTATED. THE COMPANY IS FUTURA HOME PRODUCTS, LOCATED IN THE FREEPORT CENTER IN CLEARFIELD, UTAH.

Keywords: AMPUTATED, PRESS BRAKE, FINGER, POINT OF OPERATION, HAND, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3279387 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close