Accident Summary Nr: 14446900 - Employee Injured in Fall from Scaffold

Accident Summary Nr: 14446900 -- Report ID: 0552700 -- Event Date: 06/28/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1492745306/29/198417410Amendola Construction Co Inc

Abstract: On June 28, 1984, at 1350 hours, Employee #1 was engaged in tuck-point operations. He was setting up outrigger jacks between the WACO walk-through frame scaffold and the wall. The outriggers were to support the scaffold planks. There was a wall tie on the outside frame of the scaffold at the fourth scaffold stage that prevented placement of the jack, so he decided to descend the scaffold end frames to get a wrench to loosen the tie. He was about 26 feet above the adjacent roof elevation at the fourth stage of the scaffolding. The roof was 12 feet above the ground. Somewhere between his starting point and the roof he lost his grip and fell; first to the roof, then onto the ground. No one saw him fall, and he could not remember how far he had descended before he fell. The fall resulted in a concussion, fractured elbow and pelvis, a collapsed lung, and damage to the pancreas and spleen. He was hospitalized for his injuries. His spleen later had to be removed because of extensive damage.

Keywords: FRACTURE, LUNG, SPLEEN, PANCREAS, PELVIS, FALL, CONCUSSION, ELBOW, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14927453 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close