Accident Summary Nr: 14446744 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
---|---|---|---|---|
111611026 | 05/22/1990 | 1521 | 0 | Kiminski Cement Works |
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
111611018 | 05/22/1990 | 3271 | 0 | Brenny-Dahl Block Co., Inc. |
Abstract: AN EMPLOYEE WAS UNLOADING CONCRETE BLOCKS AT A CONSTRUCTION SITE. HE WAS OPERATING THE BOOM ON HIS TRUCK BY MEANS OF A REMOTE CONTROL WHILE HE WAS STANDING ON THE GROUND. THE TRUCK WAS PARKED NEAR AN OVERHEAD POWER LINE, WHICH WAS LOCATED 18.75 FEET AWAY (CENTERLINE TO CENTERLINE). THE TRUCK WAS EQUIPPED WITH AN OHIO CRANE WITH A 22-FOOT-LONG BOOM. THE EMPLOYEE ROTATED AND RAISED THE BOOM UNTIL IT WAS 12.5 FEET ABOVE THE GROUND, THEN HE LOWERED IT INTO THE POWER LINE. THE EMPLOYEE WAS ELECTROCUTED.
Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111611026 | Occupation Not Listed | ||||
2 | 111611018 | Fatality | Electric Shock | Truck drivers, heavy |