Accident: 14443170 - Fall Down Dumbwaiter Shaft

Accident: 14443170 -- Report ID: 0355111 -- Event Date: 11/17/1984
InspectionOpen DateSICEstablishment Name
1523913011/19/19841742Sweeney Company Of Maryland
EMPLOYEE WAS FRAMING INTERIOR WALLS AND DUMBWAITER SHAFT FOR DRYWALL INSTALLATION ON 6TH FLOOR OF A CONSTRUCTION SITE. DURING THE COURSE OF THIS WORK EMPLOYEE REMOVED FLOOR OPENING COVER TO FIND OR CHALK LAYOUT LINES. HE SUBSEQUENTLY FELL THRU 40" X 41" OPENING TO THE BASE OF THE SHAFT 7 FLOORS BELOW.. HE SUSTAINED FATAL INJURIES. FATALITY COULD HAVE BEEN PREVENTED HAD TEMPORARY FLOORS BEEN INSTALLED AT LOWER LEVELS AND HAD THE EMPLOYER IMPLEMENTED A STRICT POLICY OF REQUIRING THE USE OF SAFETY BELTS ATTACHED TO APPROPRIATE LIFELINES WHEN WORKING AROUND OPEN SHAFTS.
Keywords: cover, open shaft, fall, floor opening, temporary floor
Employee # Inspection Age Sex Degree Nature Occupation
1 15239130 Fatality Fracture Drywall installers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.