Accident Report Detail
Accident Summary Nr: 14422398 - EMPLOYEE KILLED WHEN STRUCK BY FALLING BOOM
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 106022312 | 08/23/1989 | 1794 | 0 | Mcpherson Concrete Products, Inc. |
Abstract: Employee #2 was using a Bucy Rus Erie 25 "b" 28.3-ton crawler crane to unload a redi-mix concrete truck. They had made five or six, 0.75-yard bucket hoists with a boom angle of 35 degrees with no problem. On the next hoist the boom raised the bucket a few inches and the boom support cable snapped. The boom fell on the redi-mix truck, bounced off and struck Employee #1 killing him instantly.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 106022312 | Fatality | Other | Occupation not reported |
Translate