Accident Summary Nr: 144157.015 - Tree worker is electrocuted by fallen overhead power line

Accident Summary Nr: 144157.015 -- Report ID: 0523300 -- Event Date: 03/01/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1580911.01503/01/2022561730Tree Wise Men Llc

Abstract: At 1:50 p.m. on March 1, 2022, an employee was working for a landscaping service. He was working on the ground, collecting and cutting tree sections. A second employee was working as the operator of an aerial bucket lift. He was cutting tree sections to be lowered by a grapple knuckleboom crane, which was operated by a third employee. The crane was a truck-mounted PM-44 articulating boom crane, outfitted with a KRPAN 60-inch (1.5-meter) log grapple. The log grapple or hook had a sling attached for carrying the sections. The crane lowered the sections to the ground for the groundworker to collect and make further cuts. The sections being cut and lowered were over 30 feet (9.1 meters) in length. There were live (energized) overhead power lines nearby. A tree section being lowered struck the top phase conductor. The conductor broke and landed near where the employee on the ground was positioned. He was electrocuted. He was pronounced dead at the site. The event occurred outdoors, with fair weather and low wind speeds. Weather was most likely not a factor. Measurements were made or collected after the incident. From information provided by the electric utility and the employer, the overhead power line was energized at 69 kV. The uppermost phase conductor was approximately 48 feet (14.6 meters) above the ground. From the manual, the PM-44 articulating boom crane outfitted with a KRPAN 60-inch log grapple had a horizontal reach of 43 feet (13.1 meters) and a vertical reach of 54 feet 11 inches (16.7 meters). The employer provided a graph that showed a horizontal reach of 45 feet (13.7 meters) and a vertical reach of 55 feet (16.8 meters). From sales information, the aerial bucket lift had a 56-foot (17.1-meter) lift height. The distance from the tree line to the power lines was measured from on the ground. It was about 20 feet (6.1 meters). The employer said in a written response that there was a safe zone of 30 feet (9.1 meters) between any live conductor and the trees.

Keywords: Crane, Electric Shock, Electrocuted, Energized, Falling Object, Landscaper, Landscaping, Lift Bucket, Overhead Power Line, Power Lines, Protective Grounding, System Grounding, Tree, Tree Boom, Tree Trimming

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1580911.015 38 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close