Accident Report Detail
Accident Summary Nr: 14391668 - Employee killed when struck by backing dump truck
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 102277415 | 04/10/1991 | 1629 | 0 | David Bewley Construction Co. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 102277407 | 04/10/1991 | 1629 | 0 | R. L. Bellard |
Abstract: On March 29, 1991, Employee #1, a truck driver, age 48, was driving a dump truck owned by David Bewley Construction Co. at a work site along Louisiana Highway 1, five miles north of Conshatta, LA. Rock was being unloaded by power shovel from railroad cars into waiting dump trucks for transport to a dike construction site on the Red River. At approximately 10:00 a.m., Employee #1 walked back to his truck down the middle of the dirt road near the loading operation. He was backed over by a Ford L9000 dump truck, serial #290VVV76531, which was owned by R. C. Bellard, another truck owner/operator. Employee #1 was killed. The truck did not have an operable back-up alarm. Coworkers tried to get the attention of either Employee #1 or the backing truck driver by shouting or blowing vehicle horns.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 102277415 | Fatality | Fracture | Occupation not reported | ||
| 2 | 102277407 | Occupation Not Listed |