Accident Report Detail
Accident: 14382907 - Employee Killed When Crushed By Collapsing Crane Boom
Accident: 14382907 -- Report ID: 0521400 -- Event Date: 06/02/1986 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
2348795 | 06/24/1986 | 1611 | Leininger Mid-States Paving Company | ||||
On June 21, 1986, Employee #1 was assisting a coworker in dismantling the boom section of a truck crane. The crane boom had not been secured with cribbing or blocking. Employee #1 removed the lower boom pins while he was under the boom section. The boom fell on top of him, causing massive head injures. Employee #1 was killed. | |||||||
Keywords:
head, dismantling, unsecured, blocks, crane boom, work rules, construction, struck by, falling object
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 2348795 | Fatality | Concussion | Occupation not reported |