Accident Report Detail
Accident Summary Nr: 14371447 - INHALATION OF EXHAUST FUMES
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1334499 | 10/10/1984 | 5961 | 0 | Montgomery Ward & Co Inc |
Abstract: THE EMPLOYEES WERE FILLING ORDERS IN DEPARTMENTS 42, 41, 44 AND 45 OF THE WAREHOUSE ON OCTOBER 10, 1984, WHEN THEY INHALED EXHAUST FUMES AND GASES, INCLUDING CARBON MONOXIDE. THE GASES WERE GENERATED BY A CONSTRUCTION CREW OPERATING A VIBRATORY COMPACTOR WITH A GASOLINE-POWERED ENGINE. THE GASES WERE THEN DRAWN THRU THE WAREHOUSE BY THE EXHAUST VENTILATION FANS. THE EMPLOYEES SUSTAINED HEADACHES, DIZZINESS AND WEAKNESS, SOME TO THE POINT OF COLLAPSE. THE EMPLOYER DID NOT RECOGNIZE THE COMPLAINTS RECEIVED THE DAY BEFORE ABOUT THE FUMES FROM THE JOB. APPROPRIATE ACTIONS WERE NOT TAKEN TO ISOLATE AND/OR VENTILATE THE WORK AREAS. LATE ACTIVATION OF THE PLANT'S EXHAUST FANS NORTH OF THE RAIL DOCK LIKELY INCREASED THE EXTENT OF THE EXPOSURES. THE OPERATION WAS STOPPED AND DIESEL EQUIPMENT WAS SUBSTITUED. IN ADDITION, THE COMPANY HIRED AN INDUSTRIAL HYGIENE CONSULTANT WHO CONTINUALLY MONITORED THE THE ATMOSPHERE DURING THE REMAINDER OF THE JOB.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 2 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 3 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 4 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 5 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 6 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 7 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 8 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 9 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 10 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 11 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 12 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 13 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 14 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 15 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 16 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 17 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 18 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 19 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 20 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported | ||
| 21 | 1334499 | Hospitalized injury | Poisoning(Systemic) | Occupation not reported |