Accident Summary Nr: 14340335 - EMPLOYEE STRUCK AND KILLED BY FALLING TREE LIMB

Accident Summary Nr: 14340335 -- Report ID: 0418400 -- Event Date: 05/13/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10035724305/15/198724210Corbitt Beasley

Abstract: AT ABOUT 4 PM ON MAY 13, 1987, EMPLOYEE #1 WAS FELLING A 90 FOOT PINE TREE NEAR SOME BLACK GUM TREES. HE WAS USING A HUSQVARNA CHAIN SAW. HE WAS NOT WEARING GLOVES, LEGGINGS OR SAFETY SHOES, BUT HAD PLANNED A RETREAT PATH AND KEPT IT CLEAR BEFORE STARTING THE CUT. THE PINE TREE BEING FELLED STRUCK A BLACK GUM TREE, BREAKING OFF ONE OF THE BLACK GUM'S LIMBS WHICH FELL AND STRUCK EMPLOYEE #1, BREAKING HIS NECK. EMPLOYEE #1 DIED ABOUT 50 MINUTES LATER IN A HOSPITAL LOCATED 6 MILES AWAY. THERE WERE NO WITNESSES. CAUSES: THE EMPLOYER DID NOT ESTABLISH AND ENFORCE A PROCEDURE FOR APPRAISING THE SITUATION FOR DEAD LIMBS, LEAN OF THE TREE, WIND CONDITIONS, LOCATION OF OTHER TREES AND OTHER HAZARDS BEFORE A CUT IS STARTED. (SECTION 5(A)(1), 1910.266(A)(1) AND (E)(II)). EMPLOYER DID NOT SUPPLY, AND REQUIRE THE USE OF, GLOVES, BALLISTIC NYLON LEGGINGS, AND SAFETY BOOTS OR SHOES. (1910. 132(A), 1910.266(C)(1) AND 1910. 266(A)(1)). EMPLOYER DID NOT PROVIDE A PERSON ADEQUATELY TRAINED IN FIRST AID IN THE ABSENCE OF AN INFIRMARY, CLINIC, OR HOSPITAL LOCATED IN NEAR PROXIMITY TO THE WORKPLACE. EMPLOYER DID NOT PROVIDE FIRST AID SUPPLIES APPROVED BY A CONSULTING PHYSICIAN (INCLUDING SNAKEBITE KITS) SUFFICIENT FOR THE NUMBER OF EMPLOYEES, AND ONE SUCH KIT FOR EACH TRANSPORT VEHICLE. (29CFR 1910.151(B). SEE ALSO 1910.266(C)(1)(VII)).

Keywords: FRACTURE, TREE FELLING, TREE LIMB, TREE, NECK, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100357243 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close