Accident: 14318786 - Six Employees Injured In Explosion Of Plastic Fines

Accident: 14318786 -- Report ID: 0316700 -- Event Date: 06/12/2000
InspectionOpen DateSICEstablishment Name
11290189706/13/20003089Brentwood Industries, Incorporated
At approximately 1:00 p.m. on June 12, 2000, Employees #1 through #6 were transferring a mixture of plastic fines and lubricants.; the additives were explosive when in a suspended state, as per the Material Safety Data Sheet (MSDS). This transfer was performed by dumping the mixture from the mixer into a series of screw conveyors and then dropping the mixture from the top conveyor into a large metal silo. The transfer was approximately 75 percent complete when there was a small explosion in the #3 silo. The explosion shook the entire building and suspended large quantities of dust into the air. This dust then ignited and produced a large but quick dust explosion. The explosion blew out the walls and 50 percent of the roof. All of the six silos were damaged. Employees #1 through #6 sustained injuries ranging from first-, second-, and third-degree burns to shock, and Employees #1 through #3 were hospitalized overnight. The building was not designed as a Class 2, Division 1 location. None of the covers were dust tight, and there were no fire dams (chokes) to prevent the fire and explosion from spreading to other parts of the facility.
Keywords: burn, explosive mixing, work rules, fire, explosion, chemical reaction, plastic mfg, combustible dust, silo
Employee # Inspection Age Sex Degree Nature Occupation
1 112901897 Non Hospitalized injury Hearing Loss Occupation not reported
2 112901897 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 112901897 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 112901897 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 112901897 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
6 112901897 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.