Accident: 14306245 - Employee Killed When Unstable Genie Lift Falls

Accident: 14306245 -- Report ID: 0454713 -- Event Date: 06/24/1994
InspectionOpen DateSICEstablishment Name
12057706906/28/19941711Rock City Mechanical
Employee #1 was 7 ft above the floor on a Genie personnel lift. He was installin g all-thread and brackets on a 623 Banbury line to suspend duct work. When he ha d finished work on the longer rod, Employee #1 told the people below that he was on his way down. Employee #1 and the Genie lift fell to the concrete floor. He sustained severe head injuries and died. The Genie lift, model PLC-30 P, had not been set up with the provided outriggers, which were stacked approximately 8 fe et away from the lift.
Keywords: head, installing, outrigger, unsecured, work rules, construction, fall, set up, unstable position
Employee # Inspection Age Sex Degree Nature Occupation
1 120577069 Fatality Other Sheetmetal duct installers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.