Accident Summary Nr: 14291694 - Employee burned by hot tar when pipe ruptures

Accident Summary Nr: 14291694 -- Report ID: 0355118 -- Event Date: 11/17/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10571623702/09/198917610Valley Roofing Corporation
Inspection NrDate OpenedSICNAICSEstablishment Name
10571618702/08/198917310Varney Electric Co., Inc.

Abstract: Employee #1 was waiting for transportation home. Another employer on the job site was pumping approximately 350 degree Fahrenheit tar from a tar kettle through a 40 ft pipe onto a roof. The pipe broke and splattered tar onto Employee #1's face, hair, neck, and hands. Employee #1 was treated by a physician for second-degree burns on his hands and face and third-degree burns on his hands.

Keywords: EQUIPMENT FAILURE, PIPE, HOT TAR, HAND, BURN, CONSTRUCTION, RUPTURE, FACE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105716237 Non Hospitalized injury Burn/Scald(Heat) Sheet metal worker apprentices
2 105716187 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.