Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14291512 - Window Washer Injured In Fall From Seventh Floor

Accident: 14291512 -- Report ID: 0355118 -- Event Date: 07/08/1985
InspectionOpen DateSICEstablishment Name
335367907/09/19857349Crystal Clear, Inc.
At approximately 4:00 p.m. on July 9, 1985, Employee #1 and a coworker were cleaning windows at The First Federal Savings and Loan Building in Roanoke, VA. When Employee #1 started to lower himself over the side of the building to clean the seventh story windows, he began to fall and yelled for help. The coworker lowered himself to the ground so that he could get back to the roof to help Employee #1, but by the time he arrived on the roof Employee #1 had reached the street. He was treated by rescue personnel and transported to Roanoke Memorial Hospital, where he was admitted for treatment of multiple fractures. The friction box was threaded backward, and when Employee #1's weight was applied the rope came loose, allowing him to fall.
Keywords: window washer, fracture, work rules, fall, inattention
Employee # Inspection Age Sex Degree Nature Occupation
1 3353679 Hospitalized injury Dislocation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close