Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14278592 - TRUCK MOUNTED WORK PLATFORM FELL INTO DAM SPILLWAY

Accident Summary Nr: 14278592 -- Report ID: 0112000 -- Event Date: 06/30/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10119930507/01/198717210A. Laugeni And Son, Inc

Abstract: EMPLOYEE #1 WAS WORKING ON A SNOOPER WORK PLATFORM SANDBLASTING THE THOMASTON DAM BRIDGE. THE OUTRIGGER WAS NOT EXTENDED ON THE PASSENGER SIDE OF THE SNOOPER TRUCK AND THE INTERLOCK MIRCO SWITCHES WERE NOT OPERABLE. WHEN EMPLOYEE #1 SWUNG THE WORK PLATFORM 180 DEGREES TO WORK ON THE OTHER SIDE OF THE BRIDGE, THE TRUCK FELL OVER INTO THE DAM SPILLWAY. EMPLOYEE #1 WAS KILLED.

Keywords: PLATFORM, OUTRIGGER, WORK RULES, CONSTRUCTION, FALL, SPILLWAY, BRIDGE, SANDBLASTING, OVERTURN, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101199305 Fatality Fracture Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.