Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14256770 - Employees Asphyxiated When Exposed To Carbon Monoxide

Accident: 14256770 -- Report ID: 0453710 -- Event Date: 06/14/1988
InspectionOpen DateSICEstablishment Name
297977106/15/19883089Oneida Molded Plastics Corporation Of Nc
InspectionOpen DateSICEstablishment Name
297979706/15/19881541Construction Management Co. Of Raleigh, Inc.
InspectionOpen DateSICEstablishment Name
297978906/15/19881799Lipscomb Concrete Cutting, Inc.
InspectionOpen DateSICEstablishment Name
297939106/22/19881522Montague Building Company
InspectionOpen DateSICEstablishment Name
297977106/15/19883089Oneida Molded Plastics Corporation Of Nc
InspectionOpen DateSICEstablishment Name
297968006/21/19889229Johnston County Office Of Emergency Management
InspectionOpen DateSICEstablishment Name
297977106/15/19883089Oneida Molded Plastics Corporation Of Nc
On June 14, 1988, a contractor was using a gasoline-powered saw to cut a concrete floor at an injection molding facility. Carbon monoxide emissions from the saw were distributed throughout the plant by the air conditioning system, which uses 100 percent recirculated air. Employees #1 through #30, machine operators and assemblers at the plant, were treated at a local hospital for carbon monoxide asphyxiation. The employee's carboxyhemoglobin levels ranged from 7.2 to 28.3 percent.
Keywords: air conditioner, toxic fumes, carbon monoxide, portable power tool, carboxyhemoglobin, asphyxiated, saw, exhaust fumes, ventilation, inhalation
Employee # Inspection Age Sex Degree Nature Occupation
1 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
2 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
3 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
4 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
5 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
6 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
7 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
8 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
9 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
10 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
11 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
12 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
13 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
14 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
15 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
16 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
17 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
18 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
19 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
20 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
21 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
22 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
23 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
24 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
25 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
26 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
27 2979797 Occupation Not Listed
28 2979789 Occupation Not Listed
29 2979391 Occupation Not Listed
30 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
31 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
32 2979680 Occupation Not Listed
33 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's
34 2979771 Non Hospitalized injury Asphyxia Misc. metal,plastic,stone&glass-working mach. op's

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close