Accident Summary Nr: 14253108 - SIX INJURED IN SCAFFOLD COLLASPE

Accident Summary Nr: 14253108 -- Report ID: 0453710 -- Event Date: 08/23/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
298582808/23/198915420Pizzagalli Construction Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
298583608/23/198917410Gym Masonry, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
298585108/23/198917420R. Jones Drywall Corp.

Abstract: At 9:05 a.m. on August 23, 1989, six employees were on a 38-ft-high by 21-ft-long tubular welded frame scaffold erected outside, adjacent to a three story building. It was built of 5-ft-wide by 6-ft-4-in.-high walk through frames erected on compact soil and 2-in. by 10-in. sills, with leveling screw jacks under each leg. Work platforms, fully decked with 2-in. by 10-in. lumber were located at each 6 ft-4 in. interval of the height. Employees #1, 2 and 3 were on the 2nd and 3rd levels, stocking the scaffold with brick and mortar, and repairing common brick on the exterior of the building. Employees #4, 5 and 6 were on the 4th and 5th levels hanging insulated sheathing boards. The scaffold collapsed, apparently without warning. Employees fell anywhere from 13 to 32 ft. Employee #4 was hospitalized overnight with multiple injuries including internal bruises. Employees #1, 2, 3, 5 and 6 suffered abrasions, bruises, and/or cuts, but were released from the hospital's emergency room.

Keywords: CONCUSSION, FALL, SCAFFOLD, BRICK, ABRASION, CONTUSION, SCAFFOLD COLLAPSE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2985828 Non Hospitalized injury Bruise/Contus/Abras Brickmasons and stonemasons
2 2985828 Non Hospitalized injury Bruise/Contus/Abras Brickmasons and stonemasons
3 2985828 Non Hospitalized injury Bruise/Contus/Abras Brickmasons and stonemasons
4 2985836 Hospitalized injury Concussion Brickmasons and stonemasons
5 2985836 Non Hospitalized injury Bruise/Contus/Abras Brickmasons and stonemasons
6 2985836 Non Hospitalized injury Bruise/Contus/Abras Brickmasons and stonemasons
7 2985851 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.