Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14246268 - Employee killed, others become ill after inhaling freon 113

Accident Summary Nr: 14246268 -- Report ID: 0317000 -- Event Date: 10/04/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11604932111/19/199217990Alberto Cleaning Services, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11604928910/23/199217990Clean Harbors
Inspection NrDate OpenedSICNAICSEstablishment Name
11604927110/05/199289990Mrs. Paul'S Kitchen, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
1800259210/05/199251420Mrs. Paul'S Kitchen, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
1825299910/06/199217990M.F. Bank The Restoration Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
1825297310/08/199217990Nu Campo Service Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
1825298110/08/199217990Epr Restoration Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
1825299910/06/199217990M.F. Bank The Restoration Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
1800327710/23/199289990Holton & Dycus, Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
1800328510/23/199217990Clean Harbors
Inspection NrDate OpenedSICNAICSEstablishment Name
1800313711/18/199217990Alberto Cleaning Services, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
1800315211/20/199217990A.F.P. Commerical And Home Cleaners,Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11604926310/05/199217990M.F. Bank The Restoration Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
11604931311/17/199217990Epr Restoration Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
11604930511/18/199217990Nu Comps Services Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
11604933911/20/199217990A.F.P. Commerical And Home Cleaners,Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11604929710/23/199289990Holton & Dycus, Inc

Abstract: Employees #1 through #9 were working on a large-scale fire restoration operation at a food processing facility. Employees #1, #8, and #9 were cleaning electrical components with a solution of 90% freon 113 and 10% isopropyl alcohol applied with a Wagner high-powered airless sprayer, model 1250 HP. At the same time Employees #2, #3, #4, #5, #6, and #7 were manually cleaning common surfaces using surfactant and caustic cleaners. They were working in a sealed room measuring 30 ft. 2 in. long, 6 ft 2in. wide, and 12 ft. 6 1/2 in. high. The room had no mechanical ventilation. Employees #1, #8, and#9 wore no respiratory protection, while Employees #2, #3, #4, #5, #6, and #7 wore NET single-use dust/mist respirators, model no. 0401 (TC-21C-416). Employee #1 died from the cardiotoxic effects of freon 113. Employees #2, #3, #4, #5, #6, and #7 were hospitalized with severe nausea, dizziness, and respiratory distress. Employees #8 and #9 suffered the same symptoms but chose not to seek medical treatment. A comprehensive confined space entry program, addressing all minimally required elements, had not been developed or implemented.

Keywords: CLEANING, TOXIC FUMES, ISOPROPYL ALCOHOL, VENTILATION, FREON, WORK RULES, INHALATION, RESPIRATOR, CONFINED SPACE, CONSTRUCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116049321 Occupation Not Listed
2 116049289 Occupation Not Listed
3 116049271 Occupation Not Listed
4 18002592 Occupation Not Listed
5 18252999 Non Hospitalized injury Other Occupation not reported
6 18252973 Hospitalized injury Other Occupation not reported
7 18252981 Hospitalized injury Other Occupation not reported
8 18252981 Hospitalized injury Other Occupation not reported
9 18252981 Hospitalized injury Other Occupation not reported
10 18252981 Hospitalized injury Other Occupation not reported
11 18252981 Hospitalized injury Other Occupation not reported
12 18252999 Fatality Other Occupation not reported
13 18252999 Non Hospitalized injury Other Occupation not reported
14 18003277 Occupation Not Listed
15 18003285 Occupation Not Listed
16 18003137 Occupation Not Listed
17 18003152 Occupation Not Listed
18 116049263 Occupation Not Listed
19 116049313 Occupation Not Listed
20 116049305 Occupation Not Listed
21 116049339 Occupation Not Listed
22 116049297 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close