Accident Summary Nr: 14240972 - STRUCK BY ELEVATOR CAR

Accident Summary Nr: 14240972 -- Report ID: 0627700 -- Event Date: 05/13/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
72973106/04/198551470Gibson Meat Co

Abstract: EMPLOYEE #1 WAS ATTEMPTING TO PUSH A CARTLOAD OF BOXES INTO AN ELEVATOR CAR WHEN THE CAR FELL, STRIKING AND KILLING HER. THE CAR HAD BECOME JAMMBED AGAINST A STEEL PLATE, CAUSING THE CAR CABLE TO UNWIND FROM THE WINDING DRUM. AS SHE PUSHED THE CART INTO THE CAR THE CAR BROKE LOOSE FROM THE STEEL PLATE AND FELL ONTO EMPLOYEE #1'S SHOULDERS. SHE WAS KNOCKED TO THE FLOOR AND PINNED BY THE ELEVATOR CAR ROOF TO THE FLOOR. SHE SUFFERED MULTIPLE INJURIES TO THE HEAD, CHEST AND THROAT, AND DIED TWO DAYS LATER. THE ELEVATOR WAS SHOP BUILT, AND LACKED MANY OF THE SAFETY FEATURES REQUIRED BY ANSI A17.1-1971.

Keywords: CHEST, THROAT, HEAD, CRUSHED, STRUCK BY, ELEVATOR, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 729731 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.