Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14237796 - Struck And Killed By Rebounding Tree Limb

Accident: 14237796 -- Report ID: 0627100 -- Event Date: 08/20/1986
InspectionOpen DateSICEstablishment Name
10179455008/21/19862411James Hays Logging
EMPLOYEE #1 WALKED TOO CLOSE TO A LODGED TREE WHICH WAS BEING PULLED DOWN BY A SKIDDER. PRESSURE WAS SUDDENLY RELEASED FROM A BENT LIMB OF THE LODGED TREE. THE LIMB SNAPPED BACK, STRIKING EMPLOYEE #1 IN THE TEMPLE AND KILLING HIM.
Keywords: head, tree felling, tree limb, work rules, lodged tree, tree, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 101794550 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.