Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14237721 - Electric Shock - Ground Fault In Electric Equipment

Accident: 14237721 -- Report ID: 0627100 -- Event Date: 06/23/1986
InspectionOpen DateSICEstablishment Name
10179210906/25/19865191Farm Supply Co-Op
AN EMPLOYEE WAS ELECTROCUTED WHEN HE CONNECTED THE ATTACHMENT PLUG ON THE POWER SUPPLY CORD FOR A BATTERY CHARGER TO THE CORD CONNECTOR ON AN EXTENSION CORD SET. ALTHOUGH BOTH THE BATTERY CHARGER AND THE CORD SET WERE OF THE GROUNDING TYPE, THE GROUNDING CONDUCTOR WAS NOT CONTINUOUS. FERTILIZER HAD CORRODED THE ATTACHMENT PLUGS ON BOTH CORDS. ADDITIONALLY, THE FLOOR WAS WET.
Keywords: electrical, e gi vi, cord set, electrocuted, attachment plug, ground fault, cord connector, equipment grounding
Employee # Inspection Age Sex Degree Nature Occupation
1 101792109 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close