Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 14237309 - Employee Crushed And Killed By Crane Boom

Accident: 14237309 -- Report ID: 0626600 -- Event Date: 02/16/1985
InspectionOpen DateSICEstablishment Name
160839702/20/19851542Lem Construction Co Inc
Employee #1 was dismantling the boom of a Link Belt crawler crane, model IS 98 A #307. He lowered the boom, but left the peak of the boom 2 to 3 ft above the ground. It was not blocked or cribbed. While there was tension on the main pendants, he disconnected the bottom pins of a joint located behind the joint where the main pendants were connected. Boom sections rotated on the top pins, allowing the boom to fall and strike Employee #1 on the upper body. He was killed.
Keywords: dismantling, unsecured, crane boom, work rules, construction, crushed, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 1608397 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close