Accident: 14199780 - Employee Hospitalized From Carbon Monoxide Poisoning

Accident: 14199780 -- Report ID: 0352450 -- Event Date: 01/11/1985
InspectionOpen DateSICEstablishment Name
1486362501/11/19855148J. L. Weinstein Company Incorporated
Employee #1 was rotating produce using a Clark propane powered industrial lift truck (Serial No. 235, -1473, -2282) in an enclosed, refrigerated room. The room was approximately 56 ft long by 26 ft wide by 18 feet high with an 8-ft by 8-ft door, covered by hinging, overlapping plastic strips. Employee #1 ran the propane powered lift truck for 1.5 hours and then stopped after he was warned by fellow employees of the dangers associated with running the lift truck in the unventilated room for an extended period of time. He went back into the room and ran the lift truck for an additional three hours. The employee began to feel weak with dimmed vision, a rapid heartbeat, and experienced impaired hearing. From his carboxyhemoglobin blood count, it was calculated that his 8-hr TWA exposure to carbon monoxide was in a range of 208 to 357 ppm. Sampling of the lift trucks exhaust showed it emitting 350 ppm of carbon monoxide. Employee #1 was hospitalized for carbon monoxide poisoning.
Keywords: industrial truck, carboxyhemoglobin, carbon monoxide
Employee # Inspection Age Sex Degree Nature Occupation
1 14863625 Hospitalized injury Asphyxia Industrial truck and tractor equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close