Accident Summary Nr: 14198600 - FIVE EMPLOYEES INJURED IN FALL FROM SCAFFOLD PLATFORM
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 108407024 | 06/05/1989 | 1741 | 0 | Allen Tyler & Son Inc |
Abstract: Employees #1 through #5 were working on the platform of a Morgan Tower scaffold, located 19 feet, 4 inches above the ground. A cotter pin was missing from the sheave pin, which molds the 4-inch sheave in the sheave assembly. Two employees raised the scaffold by turning the winch lifting leaver, causing the sheave pin to come out. The winch cable was then free with nothing to support the carriage and platform. The scaffold platform fell and all 5 employees fell to the ground. Employees #1 through #5 were taken to the hospital, suffering from multiple injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108407024 | Hospitalized injury | Other | Construction trades, n.e.c. | ||
| 2 | 108407024 | Hospitalized injury | Other | Brickmasons and stonemasons | ||
| 3 | 108407024 | Hospitalized injury | Other | Brickmasons and stonemasons | ||
| 4 | 108407024 | Hospitalized injury | Other | Construction trades, n.e.c. | ||
| 5 | 108407024 | Hospitalized injury | Other | Brickmasons and stonemasons |