Accident: 133080.015 - Employee Is Killed When Asphyxiated While Wearing Supplied A

Accident: 133080.015 -- Report ID: 0522300 -- Event Date: 02/04/2021
InspectionOpen DateSICEstablishment Name
1513695.01502/05/2021Brilex Industries Inc.
At 5:00 p.m. on February 4, 2021, an employee was working for a firm that manufa ctured fabricated structural metal. He was performing abrasive blasting with ste el shot. He was wearing a supplied air respirator (SAR). While using the supplie d air hood, he lost consciousness. A pressure testing operation downstream on th e plant air line allowed nitrogen to backfill into the compressed air line. This test introduced an asphyxiant into the system. The employee was killed.
Keywords: abrasive blasting, air line respirator, air pressure, asphyxiated, compressed air, metal shop, nitrogen, oxygen deficiency, respirator, unconsciousness
Employee # Inspection Age Sex Degree Nature
1 1513695.015 62 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.