Accident: 123670.015 - Employee Dies When Object Is Ejected From Cnc Lathe And Stri

Accident: 123670.015 -- Report ID: 0316400 -- Event Date: 01/30/2020
InspectionOpen DateSICEstablishment Name
1460330.01501/31/2020Wooten Machine Company, Inc.
At approximately 3:15 p.m. on January 30, 2020, Employee #1 was operating a CNC Lathe, drilling a small hydraulic cylinder. Employee #1 switched from the drilli ng bit to the boring bit. As this process started, the boring bit came into cont act with the hydraulic cylinder housing causing it to be pulled from the chuck j aws. The cylinder and housing broke through the glass on the lathe door, strikin g Employee #1. Employee #1 suffered a wound to the neck and later died at the ho spital.
Keywords: cylinder, drill operator, flying object, lathe, neck
Employee # Inspection Age Sex Degree Nature
1 1460330.015 40 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.