Accident: 119958858 - Two Employees Injured In Fall When Crane Boom Fails
Accident: 119958858 -- Report ID: 0950633 -- Event Date: 08/12/1997 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
119958858 | 08/12/1997 | 5046 | Fortune Signs Corp | ||||
At approximately 7:24 a.m. on August 12, 1997, Employees #1 and #2 and two coworkers were engaged in a large commercial sign replacement project. They were using a Baldwin-Ward truck-mounted crane to access the sign structure, and were at a height of approximately 70 ft when a segment of the telescoping boom failed. Employees #1 and #2 were riding with the sign and sustained injuries when they fell. Employee #1 was transported to Bullhead Community Hospital, where he was treated and released. Employee #2 was transported by air ambulance to the University of Las Vegas Medical Center, where he was admitted for treatment. | |||||||
Keywords:
collapse, crane boom, truck crane, equipment failure, fall, mech mat handling, advertising sign, elevated work plat, crane
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 119958858 | Non Hospitalized injury | Fracture | Assemblers | |||
2 | 119958858 | Hospitalized injury | Amputation | Assemblers |