Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 116733.015 - Employee Is Killed When Caught Between Forklift And Steel Su

Accident: 116733.015 -- Report ID: 0626700 -- Event Date: 06/02/2019
InspectionOpen DateSICEstablishment Name
1405014.01506/02/2019Brw Metal Industries Llc
At 9:00 a.m. on June 2, 2019, Employee #1 and a coworker were constructing a car port. Employee #1, working from a basket attached to the forks of a rough terra in forklift, was placing purlins on top of the carport. His coworker was operat ing the forklift. Employee #1 needed to move forward to extend the purlins. Hi s coworker began to move the forklift forward. The coworker then inadvertently hit the accelerator when he meant to hit the brake. Employee #1 was caught betw een the steel support and the forklift, and his head and neck sustained crushing injuries. Employee #1 was killed.
Keywords: accelerator pedal, aerial lift, aerial lift controls, beam, caught between, construction, crushed, crushing, head, industrial truck, material handling, neck
Employee # Inspection Age Sex Degree Nature Occupation
1 1405014.015 31 M Fatality Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close