Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 105985.015 - Employee Dies Inside Tanker Trailer From Chemical Asphyxia

Accident: 105985.015 -- Report ID: 0522500 -- Event Date: 05/25/2018
InspectionOpen DateSICEstablishment Name
1318984.01505/29/2018Express Container Service Of Columbus, Llc
At 8:15 p.m. on May 25, 2018, Employee #1 was power washing the outside of the semi-truck tanker trailer. The employee entered the tanker trailer to wash the inside and was not found for two hours. The fire department was called to rescue the employee. Atmospheric monitoring found atmospheric levels of hydrogen sulfide at 100 ppm and hydrogen cyanide at 30 ppm. No written evidence of atmospheric monitoring was available following the employee's recovery from the space, and no ventilation of the space prior to or during the entry was performed. No attendant or entry supervisor was assigned to the entry. Employee #1's death was determined to be chemical asphyxia by vitiated atmosphere with hydrogen sulfide and hydrogen cyanide gasses.
Keywords: toxic atmosphere, toxic fumes, chemical vapor, cyanide, hydrogen sulfide, asphyxiated
Employee # Inspection Age Sex Degree Nature Occupation
1 1318984.015 49 M Fatality Asphyxia Laborers, except construction
2 1318984.015 49 M Fatality Asphyxia Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close