Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 893552.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 05/13/2013 2
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 03/13/2013
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 04/03/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/03/2013 | $0.00 | 05/13/2013 | Serious | |
Penalty | Z: Issued | 03/13/2013 | $2,800.00 | 04/29/2013 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Twister Room - The belt and pulley assembly on the two twisters were not guarded.