Violation Detail
Standard Cited: 19260451 B05 I General requirements.
Inspection Nr: 448073.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 09/14/2012 5
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/13/2012
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0317000
Contest Date:
Final Order: 11/01/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/13/2012 | $0.00 | 09/14/2012 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1926.451(b)(5)(i): Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the cantilevered portion of the platforms on the supported tubular welded frame scaffold extended more than 12 inches over their support which exposed the employees to tip over hazards. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.