Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1685205.015
Citation: 01004
Citation Type: Serious
Abatement Date: 04/15/2024 2
Initial Penalty: $11,292.00
Current Penalty: $4,516.80
Issuance Date: 01/24/2024
Nr Instances: 5
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 02/16/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/16/2024 | $4,516.80 | 04/15/2024 | Serious | |
Penalty | Z: Issued | 01/24/2024 | $11,292.00 | 02/20/2024 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about July 24, 2023, in the Main Shop and Tank Shop, employees performed various servicing such as set up, blade changes, and cleaning on equipment including, but not limited to press brakes, band saws, plasma tables, slip rollers, and punches used for the fabrication of tanks on the following instances: a) AccurPress Hydraulic Press Brake, Main shop, east wall. b) Hyd-Mech Bandsaw, Tank shop, south wall. c) BOSS Plasma Table, Main shop, east wall. d) MPR-E Series Slip Roller. Main shop, east wall. e) GEKA Punch, Tank shop, south wall.