Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1592628.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 1
Initial Penalty: $4,490.00
Current Penalty: $0.00
Issuance Date: 10/21/2022
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0419400
Contest Date: 11/16/2022
Final Order: 10/02/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/02/2023 | $0.00 | Serious | ||
Penalty | C: Contested | 07/10/2023 | $4,490.00 | Serious | ||
Penalty | Z: Issued | 10/21/2022 | $4,490.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(c)(4)(i):Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves. a. PCM Curing Line/Pillow Line 2 - On or about May 11, 2022, the conveyor motor shaft extended approximately 3 inches from the motor exposing employees to an entanglement hazard.