Violation Detail
Standard Cited: 19100146 E01 Permit-required confined spaces
Inspection Nr: 1535053.015
Citation: 01003
Citation Type: Serious
Abatement Date: 12/28/2021 2
Initial Penalty: $5,461.00
Current Penalty: $5,461.00
Issuance Date: 11/29/2021
Nr Instances: 3
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 12/20/2021
Emphasis:
Substance: 1480
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/20/2021 | $5,461.00 | 12/28/2021 | Serious | |
Penalty | Z: Issued | 11/29/2021 | $5,461.00 | 12/28/2021 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.146(e)(1):Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit: On or about June 7, 2021, Employees were exposed to hazards associated with confined space entry due to the fact the Employer failed to ensure confined space entry permits were completed prior to entering sewer manholes.