Violation Detail
Standard Cited: 19260651 I02 Specific Excavation Requirements.
Inspection Nr: 1440686.015
Citation: 01002
Citation Type: Serious
Abatement Date: 12/31/2019 5
Initial Penalty: $3,978.00
Current Penalty: $3,978.00
Issuance Date: 12/16/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 01/13/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 12/16/2019 | $3,978.00 | 12/31/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(i)(2): Excavation below the level of the base or footing of any foundation or retaining wall that could be reasonably expected to pose a hazard to the employees was not prohibited. Location: Jobsite 12 Carson Street Dorchester MA. On or about October 28, 2019, an employee was expose to structural collapse hazards while working in and under a residential structure where the footing and foundation had been compromised during excavation and was not properly supported.